| 1 | Glass magnesium facings / high-density rock wool core / glass magnesium facings | 200 mm | 120–150 kg/m³ | 0.039 W/m·K | 5.30 m²·K/W | 0.19 W/m²·K | Cold stores, low-energy industrial buildings, logistics centers, and temperature-controlled rooms | Use structural support designed for the panel span; stagger joints, compress longitudinal seals, and seal all penetrations with compatible fire-rated materials. | ISO 6946 heat-flow calculation; EN 14509 principles for factory-made double-skin panels; EN 13162 for mineral wool insulation; EN 13501-1 for reaction-to-fire classification. |
| 2 | Glass magnesium facings / 150 mm rock wool core / glass magnesium facings | 150 mm | 120–150 kg/m³ | 0.039 W/m·K | 4.02 m²·K/W | 0.25 W/m²·K | External walls of factories, warehouses, workshops, and commercial buildings | Install on aligned, corrosion-protected secondary steelwork; maintain panel orientation, fastener edge distances, and continuous joint sealing. | ISO 6946; EN 13162 declared thermal properties; EN 14509 mechanical and thermal design principles; EN 13501-1 fire classification where required. |
| 3 | Glass magnesium facings / 120 mm rock wool core / glass magnesium facings | 120 mm | 120–150 kg/m³ | 0.039 W/m·K | 3.25 m²·K/W | 0.31 W/m²·K | Industrial façades, public buildings, educational facilities, and office extensions | Keep boards dry before installation; use lifting equipment for long panels; close cut edges and protect the core from moisture. | ISO 6946; EN 13162; EN 14509; EN 13501-1. Fire resistance of the complete wall must be established by a tested assembly, not by the core alone. |
| 4 | Glass magnesium facings / 150 mm rock wool core with enhanced fire-density grade / glass magnesium facings | 150 mm | 140–180 kg/m³ | 0.040 W/m·K | 3.92 m²·K/W | 0.26 W/m²·K | Fire-sensitive industrial buildings, plant rooms, stair enclosures, and compartment walls | Use non-combustible or tested fire-rated joint components; avoid unsealed voids around penetrations and follow the tested fixing pattern. | EN 13501-1 reaction to fire; EN 1364-1 or applicable fire-resistance testing for wall assemblies; ISO 6946; EN 13162. |
| 5 | Glass magnesium facings / 100 mm rock wool core / glass magnesium facings | 100 mm | 120–150 kg/m³ | 0.039 W/m·K | 2.74 m²·K/W | 0.36 W/m²·K | General warehouse walls, agricultural buildings, retail storage, and interior partitions | Fix panels perpendicular to supports unless the structural design states otherwise; use washers suitable for the facing and seal side laps continuously. | ISO 6946; EN 13162; EN 14509 design approach; EN 13501-1 where a fire classification is specified. |
| 6 | Glass magnesium facings / 120 mm rock wool core / glass magnesium facings for roof use | 120 mm | 120–150 kg/m³ | 0.040 W/m·K | 3.17 m²·K/W | 0.32 W/m²·K | Industrial roofs, cold-climate warehouses, production halls, and low-slope roof systems | Provide designed roof falls and drainage; install approved weather seals, roof fasteners, flashings, and temporary protection against standing water. | ISO 6946 for roof U-value; EN 13162; EN 14509 where applicable; project-specific wind, snow, condensation, and waterproofing requirements. |
| 7 | Glass magnesium facings / 100 mm rock wool core with improved thermal grade / glass magnesium facings | 100 mm | 100–130 kg/m³ | 0.036 W/m·K | 2.95 m²·K/W | 0.34 W/m²·K | Commercial façades, modular buildings, offices, and building refurbishment projects | Check facing compatibility with adhesives and coatings; maintain a dry cavity, close perimeter gaps, and avoid compressing the insulation core. | ISO 6946; EN 13162 product thermal data; EN 14509 principles; EN 13501-1 classification must be confirmed for the complete panel. |
| 8 | Glass magnesium facings / 80 mm rock wool core / glass magnesium facings | 80 mm | 100–130 kg/m³ | 0.036 W/m·K | 2.39 m²·K/W | 0.42 W/m²·K | Interior partitions, plant rooms, temporary buildings, and moderate-climate envelopes | Use level supports and approved self-drilling fasteners; seal vertical and horizontal joints to limit air leakage and acoustic flanking. | ISO 6946; EN 13162; EN 14509 where the product is assessed as a factory-made sandwich panel; EN 13501-1 where required. |
| 9 | Glass magnesium facings / 75 mm rock wool core / glass magnesium facings | 75 mm | 100–130 kg/m³ | 0.040 W/m·K | 2.05 m²·K/W | 0.49 W/m²·K | Interior wall systems, workshops, site offices, and non-residential partitions | Install panels plumb and square; protect cut edges, provide movement allowance at abutments, and use sealed trims at openings. | ISO 6946; EN 13162; EN 13501-1 for fire reaction; acoustic and structural performance require separate project testing or calculation. |
| 10 | Glass magnesium facings / 50 mm rock wool core / glass magnesium facings | 50 mm | 100–130 kg/m³ | 0.040 W/m·K | 1.42 m²·K/W | 0.70 W/m²·K | Interior partitions, acoustic enclosures, equipment rooms, and warm-climate ancillary buildings | Use for spans and exposure conditions within the panel design limits; seal all perimeter junctions and protect the board surface during handling. | ISO 6946; EN 13162; EN 13501-1 where fire performance is required; structural suitability must be checked for the intended span and loading. |